It's not the same issue. The vast majority of kitchens in the US have 20 amp circuits (so 2,400 watts peak, 1,920 watts continuous) exclusively. It's a bog standard receptacle (NEMA 5-20R instead of 5-15R) that's backwards compatible with 15 amp plugs. In fact these days most 5-15R receptacles have identical guts to their 20 amp counterparts save for the additional provision for a horizontal blade.

The electrical code (NEC) has started moving towards requiring 20 amp circuits in other rooms and more 20 amp circuits in kitchens.


Replies

Dylan1680711/09/2025

But they're staying shy of the amp limit on purpose. So designing for 20 amps would be somewhat of a boost but not enough. While doubling voltage would actually fix the problem.