Not going to happen. For the same reason that the US never converted to a higher domestic voltage even though there are many practical advantages. The transition from one system to another at the consumer level would be terrible, even if there would be some advantage (and I'm not sure the one you list is even valid, you'd get DC-DC converters instead because your consumers typically use a lower voltage than the house distribution network powering your sockets) it would be offset by the cost of maintaining two systems side by side for decades.

You could wire your house for 12, 24 or 48V DC tomorrow and some off-grid dwellers have done just that. But since inverters have become cheap enough such installations are becoming more and more rare. The only place where you still see that is in cars, trucks and vessels.

And if you thought cooking water in a camper on an inverter is tricky wait until you start running things like washing machines and other large appliances off low voltage DC. You'll be using massive cables the cost of which will outweigh any savings.


Replies

manwe150today at 3:08 AM

I suppose that still begs the question somewhat, since the US does have 240V (2 phase) already driving many appliances. Why hasn’t it ever become standard for luxury kitchens to have a European-style outlet for use with a European kettle? I know the US already has a different 240V plug shape, so it might have to be an unlicensed installation, but surely someone wanted hot tea faster and did that calculus before?

show 8 replies
throw0101ctoday at 10:44 AM

> Not going to happen. For the same reason that the US never converted to a higher domestic voltage even though there are many practical advantages.

It would be relatively easy for the US to go to 240V: swap out single-pole breakers for double-pole, and change your NEMA 5 plugs for NEMA 6.

For a transition period you could easily have 240V and 120V plugs right next to each other (because of split phase you can 'splice in' 120V easily: just run cable like you would for a NEMA 14 plug: L1/L2/N/G).

What would be the real challenge would be going from 50 to 60Hz.

show 1 reply
SoftTalkertoday at 5:17 AM

I'm not sure it's likely, but I could see DC lighting start to happen in new construction. Have a single AC-to-DC converter off the main service entrance that powers hard-wired LED lighting fixtures in the house. Would probably be better than running the individual (and usually very low quality) converters in dozens of standard LED light bulbs. Would need to be standardized, codified, etc. so probably not happening soon.

show 1 reply
wincytoday at 5:47 AM

I just wish I could run my air conditioner and my desktop computer at the same time without flipping the breaker. The RTX 5090 is a space heater and will easily peg at the 600W it’s rated for, and so with that and an air conditioner window unit, I have to run a long cable from another unused room if I want to do anything that stresses the video card.

show 1 reply