logoalt Hacker News

bluGillyesterday at 12:55 PM2 repliesview on HN

Most large scale systems are AC because transformers are relatively cheap, low maintenance, and efficient. When the system is AC ground makes no difference.

With DC systems you generally think about the issues - which is why modern cars are negative ground. However other than cars most people never encounter power systems of any size - inside a computer the voltages and distances are usually small enough that it doesn't matter what ground is. Not to mention most computers don't even have a chassis ground plane (there are circuit board ground planes but they conceptually different), and with non-conductive (plastic) cases ground doesn't even make sense.


Replies

jcalvinowensyesterday at 2:17 PM

> When the system is AC ground makes no difference.

With AC it's about where the ground is attached along the length of the transformer secondary. In the EU they ground one of the ends of the secondary, in the US we ground the center point.

I don't get to say this very often ... but the US way is objectively safer with no downside: 99% of human shocks are via ground, and it halves the voltage to ground (120V vs 240V). A neutral isn't required if there aren't 120V loads.

show 2 replies
marcosdumayyesterday at 11:20 PM

> because transformers are relatively cheap, low maintenance, and efficient

And because that problem of galvanic corrosion the GGP talked about, and the mirror one of material aggregation don't happen. And it also makes switches more reliable.

Both are less dangerous on telephone lines. But are very important on electricity ones.

1 - It won't break your posts, but can easily short small contacts.