Might want to increase humidity. In ESD rooms the humidity is controlled and kept high to reduce static build up.
to add:
> In my particular case, my chair wheels are made out of plastic (non-conductive), so my solution was to “ground” my chair by adding a metallic chain from the chair to my room floor. I got the idea from reddit.
The chain grounded chair is used all the time in ESD rooms. The floors in these rooms use semi-conductive flooring which is tied to a ground rod. The chair is grounded to the floor which is in turn ground bonded to earth.
This. I had a huge problem with static shocking my desk in the dry winter air, causing my monitor to blank out for a few seconds. A small, quiet ultrasonic humidifier completely eliminated the problem.
On a side note, distilled water is highly recommended with ultrasonic humidifiers. Heat-based devices evaporate solely the water and leave mineral deposits behind. Ultrasonics create tiny droplets _along with the dissolved minerals_. Hard tap water or mineralized drinking water will coat your work area in chalk-like dust.