lisper • yesterday at 9:05 PM • 1 reply • view on HN

> The ball is forced downwards when the trigger is pulled because liquid initially flows towards the dip tube

Actually, gravity makes the ball drop as soon as the trigger stops moving.

> Once the trigger is released, reduced pressure in the chamber causes liquid to flow up the dip tube

This doesn't explain why the reduced pressure doesn't draw fluid back in through the discharge. And the answer to that is that the discharge hole is very small. So the fact that this is a spray bottle designed for non-viscous fluids is actually integral to the design. If you want to pump a viscous fluid like soap you need a different design.


Replies

QGQBGdeZREunxLe • yesterday at 9:21 PM

> Actually, gravity makes the ball drop as soon as the trigger stops moving.

Gravity helps the ball return to its seat, although not strictly necessary given that reverse flow pushes it downwards.

> This doesn't explain why the reduced pressure doesn't draw fluid back in through the discharge. And the answer to that is that the discharge hole is very small. So the fact that this is a spray bottle designed for non-viscous fluids is actually integral to the design. If you want to pump a viscous fluid like soap you need a different design.

The original patent describes a second check valve (300). The conical skirt (312) flexes inwards under pressure, allowing liquid to flow towards the nozzle, but otherwise forms a seal against the surrounding wall.

So preventing backflow through the nozzle does not depend on the size of the discharge hole in this design.